INSUL JACKET NOM O.D. COPPER WT NET WT
COND. SIZE
COND.
FR-EPR/CPE Shielded Control 600V PART NUMBER (AWG) COND. STRAND THICKNESS THICKNESS INCHES LBS/1000 FT LBS/1000 FT
NO. OF
INCHES
INCHES
SHEC-016-002 16 2 7/.0192 0.025 0.045 0.320 19 52
Control Cable • Shielded • 600 Volts • UL Type TC-ER 1 SHEC-016-003 16 3 7/.0192 0.025 0.045 0.335 27 66
Overall Shielded • E-2 Color Code SHEC-014-002 14 2 7/.0242 0.030 0.045 0.375 29 74
SHEC-014-003 14 3 7/.0242 0.030 0.045 0.395 42 95
CONDUCTOR SHEC-014-004 14 4 7/.0242 0.030 0.045 0.430 55 118
• 16 AWG thru 10 AWG fully annealed stranded tinned copper per ASTM B33 SHEC-014-005 14 5 7/.0242 0.030 0.045 0.470 68 142
• Class B stranding per ASTM B8 SHEC-014-007 14 7 7/.0242 0.030 0.045 0.510 94 176
SHEC-014-009 14 9 7/.0242 0.030 0.060 0.625 121 243
INSULATION
SHEC-014-012 14 12 7/.0242 0.030 0.060 0.705 160 304
• Flame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
• Color-coded per ICEA Method 1, Table E-2 (does not include white or green) SHEC-014-019 14 19 7/.0242 0.030 0.060 0.820 252 471
SHEC-014-025 14 25 7/.0242 0.030 0.080 0.940 325 627
SHIELD SHEC-014-030 14 30 7/.0242 0.030 0.080 1.035 389 750
• Overall shielded multi-conductor cable SHEC-014-037 14 37 7/.0242 0.030 0.080 1.115 468 878
• Overall shield is aluminum/polymer in contact with stranded tinned copper drain wire
SHEC-012-002 12 2 7/.0305 0.030 0.045 0.415 43 97
JACKET SHEC-012-003 12 3 7/.0305 0.030 0.045 0.440 66 127
• Lead-free, fame-retardant thermoplastic Chlorinated Polyethylene (CPE) SHEC-012-004 12 4 7/.0305 0.030 0.045 0.480 87 160
SHEC-012-005 12 5 7/.0305 0.030 0.045 0.525 108 194
STANDARDS SHEC-012-007 12 7 7/.0305 0.030 0.060 0.600 151 271
Industry Compliances: SHEC-012-009 12 9 7/.0305 0.030 0.060 0.700 193 340
• UL 44 Type XHHW-2
SHEC-012-012 12 12 7/.0305 0.030 0.060 0.770 249 431
• UL 1277 Type TC-ER for 3 or more conductors, UL File # E57179
• UL 1581 SHEC-012-019 12 19 7/.0305 0.030 0.080 0.945 393 691
• ICEA S-73-532/NEMA WC57 SHEC-012-025 12 25 7/.0305 0.030 0.080 1.100 517 857
Flame Test Compliances: SHEC-012-030 12 30 7/.0305 0.030 0.080 1.155 620 1005
• UL 1581/UL 2556 VW-1
SHEC-012-037 12 37 7/.0305 0.030 0.080 1.245 764 1243
• UL 1685 Vertical Flame Test
• IEEE 383 SHEC-010-002 10 2 7/.0385 0.030 0.045 0.460 68 131
• IEEE 1202 SHEC-010-003 10 3 7/.0385 0.030 0.045 0.490 103 175
• CSA FT4 SHEC-010-004 10 4 7/.0385 0.030 0.060 0.565 136 237
• ICEA T-29-520
SHEC-010-005 10 5 7/.0385 0.030 0.060 0.620 170 287
Other Compliances:
• EPA 40 CFR, Part 261 for leachable SHEC-010-007 10 7 7/.0385 0.030 0.060 0.675 237 384
lead content per TCLP SHEC-010-009 10 9 7/.0385 0.030 0.060 0.765 298 467
• OSHA Acceptable SHEC-010-012 10 12 7/.0385 0.030 0.080 0.910 404 654