FR-EPR/CPE Power 600V COND. NO. OF COND. GROUND INSUL JACKET NOM O.D. COPPER WT NET WT
PART NUMBER
SIZE (AWG) COND. STRAND WIRE SIZE THICKNESS THICKNESS INCHES LBS/1000 LBS/1000
(AWG) INCHES INCHES FT FT
Low-Voltage Power Cable • Unshielded • 600 Volts PWEC-014-003G 14 3 7/.0242 14 0.030 0.045 0.390 55 118
1
UL Type TC-ER • Method 4 Color Code PWEC-012-003G 12 3 7/.0305 12 0.030 0.045 0.435 87 160
PWEC-010-003G 10 3 7/.0385 10 0.030 0.060 0.485 136 237

PWEC-008-003G 8 3 7/.0486 10 0.045 0.060 0.655 190 314
CONDUCTOR
PWEC-008-004G 8 4 7/.0486 10 0.045 0.060 0.720 242 393
• 14 AWG thru 750 kcmil tinned, annealed copper per ASTM B33
PWEC-006-003G 6 3 7/.0612 8 0.045 0.060 0.740 297 456
• Class B stranding per ASTM B8
PWEC-006-004G 6 4 7/.0612 8 0.045 0.060 0.790 384 561
INSULATION PWEC-004-003G 4 3 7/.0772 8 0.045 0.080 0.880 442 642

• Flame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II PWEC-004-004G 4 4 7/.0772 8 0.045 0.080 0.950 578 822
• Color-coded per ICEA Method 4; individual conductors colored black with
PWEC-002-003G 2 3 7/.0974 6 0.045 0.080 1.010 703 979
conductor number surface printed in contrasting ink
PWEC-002-004G 2 4 7/.0974 6 0.045 0.080 1.090 919 1235

GROUND PWEC-001-003G 1 3 19/.0664 6 0.055 0.080 1.120 872 1021
• Uninsulated tinned annealed copper per ASTM B3 PWEC-001-004G 1 4 19/.0664 6 0.055 0.080 1.235 1136 1521
• Class B stranding per ASTM B8 PWEC-110-003G 1/0 3 19/.0745 6 0.055 0.080 1.225 1069 1439

PWEC-110-004G 1/0 4 19/.0745 6 0.055 0.080 1.330 1413 1820
JACKET
PWEC-210-003G 2/0 3 19/.0837 6 0.055 0.080 1.300 1340 1720
• Lead-free, fame-retardant thermoplastic Chlorinated Polyethylene (CPE)
PWEC-210-004G 2/0 4 19/.0837 6 0.055 0.080 1.440 1760 2208
STANDARDS PWEC-310-003G 3/0 3 19/.0940 4 0.055 0.080 1.420 1717 2176
Industry Compliances: PWEC-310-004G 3/0 4 19/.0940 4 0.055 0.080 1.570 2245 2788
• UL 44 Type XHHW-2 PWEC-410-003G 4/0 3 19/.1055 4 0.055 0.080 1.540 2130 2614
• UL 1277 Type TC-ER, UL File # E57179
PWEC-410-004G 4/0 4 19/.1055 4 0.055 0.110 1.790 2796 3495
• UL 1581
• ICEA S-95-658/NEMA WC70 PWEC-250-003G 250 3 37/.0822 4 0.065 0.110 1.760 2494 3184
Flame Test Compliances: PWEC-250-004G 250 4 37/.0822 4 0.065 0.110 1.915 3282 4019
• UL 1581/UL 2556 VW-1 PWEC-350-003G 350 3 37/.0973 3 0.065 0.110 1.960 3474 4187
• UL 1685 Vertical Flame Test
PWEC-350-004G 350 4 37/.0973 3 0.065 0.110 2.165 4577 5436
• IEEE 383
• IEEE 1202 PWEC-500-003G 500 3 37/.1162 2 0.065 0.110 2.245 4934 5847
• CSA FT4 PWEC-500-004G 500 4 37/.1162 2 0.065 0.110 2.475 6509 7607
• ICEA T-29-520 PWEC-750-003G 750 3 61/.1109 1 0.080 0.140 2.810 7278 9145
Other Compliances:
PWEC-750-004G 750 4 61/.1109 1 0.080 0.140 3.115 9712 11805
• EPA 40 CFR, Part 261 for leachable
lead content per TCLP Dimensions and weights are nominal; subject to industry tolerances.
• OSHA Acceptable













industrialsales@cobrawire.com | 216-416-0477 | www.cobrawire.com
© 2015 Cobra Wire & Cable, A Genuine Cable Group Company
A GENUINE CABLE GROUP COMPANY A DIVISION OF EIS, INC. 47
   42   43   44   45   46   47   48   49   50   51   52