Page 77 - index
P. 77
®
NET WT
Firewall LSZH XHHW-2 PART NUMBER COND. SIZE (AWG) NO. OF STRANDS INS THICKNESS NOM. OVERALL DIAM LBS/1000 FT
INCHES
INCHES
FRWL-014-001 14 AWG 7 0.030 0.13 19
Low Smoke • Zero Halogen • 90ºC* • 600 Volt FRWL-012-001 12 AWG 7 0.030 0.15 28
FRWL-010-001 10 AWG 7 0.030 0.18 40
NEC Type XHHW-2 UL Listed • NFPA 130 & 502 FRWL-008-001 8 AWG 7 0.045 0.24 70
FRWL-006-001 6 AWG 7 0.045 0.27 105
FEATURES FRWL-004-001 4 AWG 7 0.045 0.32 160
FRWL-002-001 2 AWG 7 0.045 0.38 240
• Low Smoke Zero Halogen Design
• RoHS compliant insulation FRWL-001-001 1 AWG 19 0.055 0.44 305
• Thermoset insulation for enhanced thermal stability FRWL-110-001 1/0 AWG 19 0.055 0.48 375
• Specially formulated insulation for exceptional long term water resistance FRWL-210-001 2/0 AWG 19 0.055 0.52 470
• Superior fame retardance FRWL-310-001 3/0 AWG 19 0.055 0.57 590
• Excellent mechanical properties FRWL-410-001 4/0 AWG 19 0.055 0.63 730
• Tin-coated copper conductors for improved terminations and corrosion resistance FRWL-250-001 250 kcmil 37 0.065 0.70 870
• Reduced size and weight for increased raceway capacity FRWL-350-001 350 kcmil 37 0.065 0.80 1200
• Easy strippability FRWL-500-001 500 kcmil 37 0.065 0.93 1680
• Low friction surface for reduced pulling tension
FRWL-600-001 600 kcmil 61 0.080 1.05 2031
• Rated for CT use 1/0 and larger
FRWL-750-001 750 kcmil 61 0.080 1.14 2499
PERFORMANCE STANDARDS
• Insulation in accordance with ICEA and UL standards
• Passes IEEE 1202/FT4 vertical tray fame test ICEA 70,000 BTU/hr vertical fame test
• Passes UL VW-1**
• Passes vertical fame test Type A as defned in ICEA S-95-658 (6.8.2)
• UL listed as Type ST1 (Limited Smoke)
• UL approved 90º for both wet and dry locations
• UL listed for sunlight resistance (Black)
• UL listed as gasoline and oil resistant SCOPE
• Meets the requirements of NFPA 130 & 502 as applicable Firewall LSZH XHHW-2 is a one conductor, unjacketed,
®
power cable. Its tough thermoset construction allows for its
CONSTRUCTION
use in demanding applications without additional jacketing
• Conductor: Annealed, tin-coated copper, Class "B" strand per ASTM B-8 & B-33 protection. It is intended for low voltage power and lighting
(Available as solid conductors when required) functions and may be installed in trays, ducts and conduits.
• Insulation: Flame retardant low Smoke Zero Halogen crosslinked polyolefn
• Separator Tape: Helically applied polyester (where required)
• Color: Black (Available in pigmented colors or colored stripes)
* Rated 90ºC for normal operation in wet and dry locations, 130ºC for emergency overload conditions, and 250ºC for short circuit conditions.
** #10 AWG and larger.
industrialsales@cobrawire.com | 216-416-0477 | www.cobrawire.com
© 2015 Cobra Wire & Cable, A Genuine Cable Group Company
A GENUINE CABLE GROUP COMPANY A DIVISION OF EIS, INC. 77