Page 68 - index
P. 68

EPR/LSZH Copper Tape Shield 5kV



EPR/Copper Tape Shield/LSZH • Medium Voltage Power

Cable Shielded • 5kV and 8kV • UL Type MV-105/ST1
133%/100% Insulation Levels • 115 Mils



CONDUCTOR

• 6 AWG thru 1000 kcmil annealed bare copper compact Class B strand

INSULATION
• Ethylene Propylene Rubber (EPR) insulation, colored to
contrast with the black conducting shield layers


SHIELDS
• Extruded Strand Shield (ESS) - Extruded thermoset semi-
conducting stress control layer over conductor
• Extruded Insulation Shield (EIS) - Thermoset semi-conducting polymeric
layer free stripping from insulation
• Metallic Shield - 5 mil annealed copper tape with an overlap of 25%

OVERALL JACKET
• Lead-free, moisture and sunlight-resistant, Low-
Smoke, Zero-Halogen Polyolefn (LSZH)

STANDARDS

Industry Compliances:
• National Electrical Code (NEC)
• UL 1072
• ICEA S-93-639/NEMA WC74
• ICEA S-97-682
• ICEA T-33-655
• AEIC CS8
• UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501
• UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test
• UL 1685 Vertical Flame and Smoke Release Test
• Sizes 1/0 AWG and larger are listed and marked “Sunlight
Resistant FOR CT USE” in accordance with NEC
• IEEE 1202 (70,000 BTU/hr)/CSA FT4
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
Optional Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)