EXTRA FLEXIBLE MARINE BATTERY CABLE

MARINE CABLE MEETING UL & ABYC STANDARDS

DESCRIPTION

This product was designed to meet or exceed test requirements called for by Underwriters Laboratories and the National Electric Code. It is recommended for use in accordance with UL and CSA for internal wiring. The extra flexible conductors with soft drawn tinned copper meet ASTM Specification B172. It is also suitable for use in transformers, switchboard panels, controls, electronic circuits, and as battery cable, battery charger cable, motor lead, and power hook up cable.


WARNING: California Proposition 65 - Cancer and Reproductive Harm
www.P65Warnings.ca.gov

STRANDING

Class K Tinned Copper

STANDARD

UL 1426
UL Listed BC-5W2

INSUlATION

This product offers a unique flame retardant polyvinyl chloride compound (VW-1) and is moisture, abrasion, acid, diesel fuel and oil resistant. It is extremely flexible & easy to work with.

VOlTAGE

600/1000 Volts

TEMPERATURE

105°C dry, 75°C wet

Cobra Part
Number
Size Stranding
*
Insulation Nominal OD UL Style
***
AMPS
**
Cable Weight
AWG
IN
IN
LBs/MFT
A2006T 6 266 X 30 0.060 0.342 UL 1232, UL 1283, UL 10269 118 136
A2004T 4 420 X 30 0.060 0.386 UL 1232, UL 1283, UL 10269 157 189
A2002T 2 665 X 30 0.060 0.446 UL 1232, UL 1283, UL 10269 213 292
A2001T 1 836 X 30 0.080 0.520 UL 1232, UL 1284, UL 10269 246 350
A2110T 1/0 1064 X 30 0.080 0.575 UL 1232, UL 1284, UL 10269 291 450
A2120T 2/0 1330 X 30 0.080 0.610 UL 1232, UL 1284, UL 10269 336 551
A2130T 3/0 1672 X 30 0.080 0.685 UL 1232, UL 1284, UL 10269 392 672
A2140T 4/0 2109 X 30 0.080 0.745 UL 1232, UL 1284, UL 10269 454 820
Cable manufactured in accordance with the new Federal EPA Rule, Title 40-part 82, (OCD’s) *Extra flexible conductor with soft drawn tinned copper to ASTM Specifications B172.
**The 105°C cable ampacities are adapted from ICEA P-54-440/NEMA WC51-1986(R1991). The ampacities are provided for informational purposes only. Acceptance of these values by any governing authority is the responsibility of the end user. Ampacities are based on a single conductor, in free air, at 30°C ambient air temperature. 90°C ampatcities per NEC 310-17.
***6 thru 2 AWG also UL1337, 1 thru 4/0 also UL 1338, 6 thru 4/0 AWG also UL 10070.
1/0 thru 750MCM "CT" approved 1/0 thru 500MCM FT4 rated

 

Print Legend
CoBRa WIRE & CaBlE X-FlEX® E NumBER (ul) BC5W2 oR mTW oR THW FT4 oR aWm 1232/1284/1338/10070 600V oR 10269 1000V VW-1 SR aWg SIZE ll NumBER CSa TEW 105°C 600V oR aWm I a/B 105°C 600V o FT1 RoHS ComPlIaNT maDE IN uSa (FoR SIZES 1/0 aND laRgER aDD “FoR CT uSE")


UL Listed CSA