Extension | Multipair Overall Shielded | Multipair Individual & Overall Shielded
Type KX - Chromel/Alumel Insulated Extension Grade Wire
Color Code: Postive - Yellow, Negative - Red, Overall - Yellow
Construction | Insulation | AWG | Cond | Temp °F | Nominal Size |
Weight | |
---|---|---|---|---|---|---|---|
Singles | Jacket | ||||||
KX 16 SF-SF | Synthetic Fiber | Braided Synthetic Fiber | 16 | Solid | 400 | .170 X .215 | 32 |
KX 20 SF-SF | Synthetic Fiber | Braided Synthetic Fiber | 20 | Solid | 400 | .140 X .200 | 18 |
KX 16 FEP-FEP | FEP PTFE | FEP PTFE | 16 | Solid | 400 | .107 X .158 | 32 |
KX 20 FEP-FEP | FEP PTFE | FEP PTFE | 20 | Solid | 400 | .072 X .124 | 11 |
KX 16 FEP-AL-FEP | FEP PTFE | FEP PTFE Tw/Sh | 16 | Solid | 400 | .180 | 38 |
KX 20 FEP-AL-FEP | FEP PTFE | FEP PTFE Tw/Sh | 20 | Solid | 400 | .146 | 22 |
KX 16 GB-GB | Fiberglass | Fiberglass | 16 | Solid | 400 | .087 X .155 | 18 |
KX 20 GB-GB | Fiberglass | Fiberglass | 20 | Solid | 400 | .058 X .105 | 9 |
KX 16 PFA-PFA | PFA PTFE | PFA PTFE | 16 | Solid | 400 | .108 X .158 | 32 |
KX 20 PFA-PFA | PFA PTFE | PFA PTFE | 20 | Solid | 400 | .067 X .115 | 11 |
KX 16 PFA-AL-PFA | PFA PTFE | PFA PTFE Tw/Sh | 16 | Solid | 400 | .180 | 38 |
KX 20 PFA-AL-PFA | PFA PTFE | PFA PTFE Tw/Sh | 20 | Solid | 400 | .146 | 22 |
KX 16 K-AK-K | Polyimide | Ployimide Tw/Sh | 16 | Solid | 500 | .160 | 30 |
KX 20 K-AK-K | Polyimide | Ployimide Tw/Sh | 20 | Solid | 500 | .120 | 15 |
KX 16 PVC-PVC | Polyvinyl | Polyvinyl | 16 | Solid | 220 | .120 X .207 | 26 |
KX 16S PVC-PVC | Polyvinyl | Polyvinyl | 16 | Strd | 220 | .140 X .230 | 26 |
KX 20 PVC-PVC | Polyvinyl | Polyvinyl | 20 | Solid | 220 | .095 X .150 | 14 |
KX 20S PVC-PVC | Polyvinyl | Polyvinyl | 20 | Strd | 220 | .105 X .170 | 16 |
KX 16 PVC-AL-PVC | Polyvinyl | Polyvinyl Tw/Sh | 16 | Solid | 220 | .250 | 39 |
KX 20 PVC-AL-PVC | Polyvinyl | Polyvinyl Tw/Sh | 20 | Solid | 220 | .165 | 22 |
Overall Shielded Type KX Cable
PVC Insulation & Jacket Overall Shield
UL PLTC 300 Volt
Cable Specifications
Conductors: 20 AWG Solid Thermocouple Extension Wire
Singles Insulation: 15 mils 105°C PVC
Color Code: Jacket and individual pairs are per ANSI MC96.1
Construction: Twisted pairs
Indentification of pair: One conductor of each pair is numbered.
Twist: Lay is approximately 2.5 inches
Overall Shield: .002" aluminized poly backed tape overlapped to provide 100% coverage when flexed.
Overall Drain Wire: Stranded uninsulated tinned copper in continuous contact with shield.
Communications Wire: 22 AWG stranded copper wire insulated and color coded orange.
Ripcord: Assisits in jacket removal.
Jacket Insulation: 90°C Flame retardant PVC.
Construction | Number of Pairs |
Jacket Thickness |
O.D. | Bending Radius |
Max Pulling Tension |
Weight |
---|---|---|---|---|---|---|
KX 20 1PR PVC-AL-PVC | 1 | .035 | .220 | 1.45 | 26 | 27 |
KX 20 2PR PVC-AL-PVC | 2 | .042 | .322 | 2.00 | 40 | 50 |
KX 20 4PR PVC-AL-PVC | 4 | .042 | .370 | 2.50 | 75 | 76 |
KX 20 6PR PVC-AL-PVC | 6 | .052 | .440 | 2.70 | 105 | 110 |
KX 20 8PR PVC-AL-PVC | 8 | .052 | .475 | 3.00 | 142 | 129 |
KX 20 10PR PVC-AL-PVC | 10 | .052 | .540 | 3.25 | 170 | 155 |
KX 20 12PR PVC-AL-PVC | 12 | .052 | .560 | 3.25 | 210 | 175 |
KX 20 16PR PVC-AL-PVC | 16 | .062 | .645 | 3.70 | 275 | 230 |
KX 20 20PR PVC-AL-PVC | 20 | .062 | .670 | 4.00 | 330 | 280 |
KX 20 24PR PVC-AL-PVC | 24 | .062 | .745 | 4.80 | 405 | 325 |
KX 20 36PR PVC-AL-PVC | 36 | .072 | .890 | 6.00 | 600 | 470 |
KX 20 50PR PVC-AL-PVC | 50 | .072 | .995 | 6.00 | 830 | 640 |
Available in other gauge sizes
Individual & Overall Shielded Type KX Cable
PVC Insulation & Jacket Individual & Overall Shield
UL PLTC 300 Volt
Cable Specifications
Conductors: 20 AWG Solid Thermocouple Extension Wire
Singles Insulation: 15 mils 105°C PVC
Color Code: Jacket and individual pairs are per ANSI MC96.1
Construction: Twisted pairs
Indentification of pair: One conductor of each pair is numbered.
Twist: Lay is approximately 2.5 inches
Pair Shield: Aluminized Polyester-backed tape overlapped to provide coverage when flexed.
Pair Drain Wire: Stranded uninsulated tinned copper in continuous contact with shield.
Overall Shield: .002" aluminized poly backed tape overlapped to provide 100% coverage when flexed.
Overall Drain Wire: Stranded uninsulated tinned copper in continuous contact with shield.
Communications Wire: 22 AWG stranded copper wire insulated and color coded orange.
Ripcord: Assisits in jacket removal.
Jacket Insulation: 90°C Flame retardant PVC.
Construction | Number of Pairs |
Jacket Thickness |
O.D. | Bending Radius |
Max Pulling Tension |
Weight |
---|---|---|---|---|---|---|
KX 20 2PR PVC-AL-AL-PVC | 2 | .040 | .365 | 2.90 | 50 | 64 |
KX 20 4PR PVC-AL-AL-PVC | 4 | .052 | .450 | 3.40 | 95 | 105 |
KX 20 6PR PVC-AL-AL-PVC | 6 | .052 | .525 | 4.20 | 140 | 140 |
KX 20 8PR PVC-AL-AL-PVC | 8 | .052 | .570 | 4.45 | 180 | 170 |
KX 20 10PR PVC-AL-AL-PVC | 10 | .062 | .685 | 5.45 | 225 | 222 |
KX 20 12PR PVC-AL-AL-PVC | 12 | .062 | .690 | 5.45 | 260 | 250 |
KX 20 16PR PVC-AL-AL-PVC | 16 | .062 | .765 | 5.90 | 340 | 310 |
KX 20 20PR PVC-AL-AL-PVC | 20 | .062 | .845 | 6.70 | 430 | 375 |
KX 20 24PR PVC-AL-AL-PVC | 24 | .072 | .930 | 7.50 | 520 | 455 |
KX 20 36PR PVC-AL-AL-PVC | 36 | .072 | 1.040 | 8.20 | 780 | 625 |
KX 20 50PR PVC-AL-AL-PVC | 50 | .072 | 1.200 | 9.45 | 1090 | 835 |
Special limits of error available on certain constructions.